User's Manual

--------------------------------------------------------------------------------7/31--------------------------------------------------------------------------------
!
!
3 Short Form Operating Instruction
3.1 Installation of the battery
Slide the battery into its compartment until it clicks ((8) in Figure 2-1). Type of battery: Li-Ion
BP608 (AEG ID Order-NR. 70178).
Caution: Do use batteries Type Li-ion BP 608 only. The reader may be damaged by using batter-
ies which are not suitable. To charge the battery, remove it carefully from its compartment and
plug it into the appropriate charger.
Respect the dangers and follow the safety instructions about the proper use of rechargeable
lithium-ion batteries.
3.2 Power on / off
The reader is switched on by pressing the main but-
ton ((1) in Figure 2-1).
It is now in the Stand-by mode.
It will switch off again automatically, if no other but-
tons has been pressed within timeout.
3.3 Reading a transponder
In the Stand-by mode: press the main button.
In the power off mode: press the main button twice.
Now the reader starts the reading mode. The
display shows: Scanning....
Approach a transponder with the reader
1
.
The reader emits a beep when the tran-
sponder has been read successfully. The
transponder code is shown on the display.
If, no transponder has been read within 5 s,
the reader terminates the reading mode and
goes back to stand-by. The display shows: “ --- No Tag --- ”
3.4 Database
When a reading had been accomplished successfully - i.e. it had been performed within the given time
frame - the database will be checked whether this transponder code is already stored.
1
Typical reading distances are given in chapter 7.1
Off
Stand-by
7 5
6
12
11
10
8 4
2
1
9 3
10s
Press main button
Read
transponder
7 5
6
12
11
10
8 4
2
1
9 3
5s
Press main button
NoRead
code
read