User's Manual

Rev 09
--------------------------------------------------------------------------------15/27--------------------------------------------------------------------------------
after a warm start (command line RST <CR>)
after entering the command line CID <SP> 1 <CR>
This causes that the next transponder code is output definitely.
Note: The filter function CID picks up the results of the complete reading cycles, while the parameter
NID proceeds from the results of single readings! The filter function CID has effect on the serial in-
terface only.
3.3.2 CN – suppression of No Reads
Through the setting CN=1 the NoRead results after a get tag command or in MD0 mode are sup-
pressed on the serial interface. The leds are not influenced by this command.
Input format: CN <SP> parameter <CR>
Output (example): 0 <CR>
Parameter:
PARAMETER FUNCTION
0 No suppression
1 Suppression of equal transponder numbers