User's Manual

--------------------------------------------------------------------------------36/45--------------------------------------------------------------------------------
PARAMETER FUNCTION
0h..FFh block number
3.6.7 LDS – lock DSFID
This command locks the DSFID of a transponder. You have to do a get tag first.
Input format: LDS <CR>
Output (example): ACK <CR>
3.6.8 RTR – reset to ready
With this command the transponder enteres the ready state. A muted transponder answers again after
this command.
Input format: RTR <CR>
Output (example): ACK <CR>
3.6.9 SF – set flag
You can change the flags for different ISO 15693 commands with the command SF. For the meaning of
the flags have a look in the ISO 15693 part 3.
Input format: SF <SP> parameter 1 <SP> parameter 2 <CR>
Output (example): 00 <CR>
Parameter:
PARAMETER 1 FUNCTION
0 inventory
1 stay quiet
2 reset to ready
3 read
4 write
5 lock block
6 write/lock AFI/DSFID
7 get system information /
get multiple block security