00h limits the reading process duration of exactly one reading cycle
01h..FFh limits the reading process duration to maximum 1..256 times
TB
3.3.10 SI – set iso standard
With this command you can switch the iso standard of the reader.
Input format: SI <SP> parameter <CR>
Output (example): 0 <CR>
Parameter:
PARAMETER FUNCTION
0 ISO 14443A
1 ISO 15693
3.3.11 VSAVE – variables save
With the command VSAVE the following parameters are saved to the internal EEPROM:
AFI
2
, BD, BS, CE
1
, CID, CN, HID, KL, KM
1
, KT
1
, LAA, LED, MC, MD, SF, SI, TOR, TSC
Input format: VSAVE <CR>
Output (example): ACK <CR>
1
just available in the ISO 14443A standard
2
just available in the ISO 15693 standard
3.3.12 VS – variables show
With the command VS the reader shows the settings of the following parameters:
AFI
2
, BD, BS, CE
1
, CID, CN, HID, KL, KM
1
, KT
1
, LAA, LED, MC, MD, SF, SI, TOR, TSC
Input format: VS <CR>
Output (example): BD <SP> 0 <SP>