User's Manual
--------------------------------------------------------------------------------13/45--------------------------------------------------------------------------------
09 englisch
0A spanish
0C french
10 italien
13 dutch
16 portuguese
4B canadian
3.2.5 RE – read EEPROM
You can read out the internal EEPROM with the RE command.
Input format: RE <SP> parameter <CR>
Output (example): FF <CR>
Parameter:
PARAMETER FUNCTION
0000h..079Fh address
3.2.6 LED – LED control
With the command LED you can control the LED ring of the ARE DT1.
Input format: LED <SP> parameter <CR>
Output (example): 1 <CR>
Parameter:
PARAMETER FUNCTION
0 off
1 on
2 Buzzer beeps,
LEDs flash
final state =initial
state