User Manual

Manual ACM 9 - ARE i9 release
Version:
05
Page:
36 / 45
Manual ACM9_ARE i9 release V05.docx
3.4.11 INIT
INIT Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
4E
49
54
0D
ASCII:
‘I’
‘N’
‘I’
’T’
<CR>
Output (example): OK<CR>
Hex:
4F
4B
0D
ASCII:
‘O’
‘K’
<CR>
The following parameters are set:
TOR 50 LRD 01001
MD 2 LNRD 10001
CID 0 LERR 10011
CN 0 LED 1
LSTB 01101 LRT 30
LGT 01111 LPA 00000
3.4.12 Error messages
Error messages and protocol errors are acknowledged by ARE i9 using an error code. The format is described below:
<NAK> '#' <error code> <CR>
Example error #02 (wrong parameter)
Hex:
15
23
30
32
0D
ASCII:
<NAK>
‘#’
‘0’
’2’
<CR>
The error code is comprised of a two digit ASCII coded number. Please note that for communication through ACM 9, the
appropriate reader number is preceding the error message.
The following table displays possible error messages:
Error code
Meaning
"00"
Unknown instruction
"02"
Wrong parameter