User Manual

Manual ACM 9 - ARE i9 release
Version:
05
Page:
28 / 45
Manual ACM9_ARE i9 release V05.docx
3.3.11 VSAVE
VSAVE Save parameter permanently in ARE i9 flash memory
VSAVE is used to save parameters permanently in flash memory of ARE i9 to be available after power on.
Input format: VSAVE <CR>
Hex:
56
53
41
56
45
0D
ASCII:
‘V’
‘S’
‘A’
’V’
‘E’
<CR>
Output (example): OK<CR>
Hex:
4F
4B
0D
ASCII:
‘O’
‘K’
<CR>
3.3.12 INIT
INIT Restore standard parameters. Command needs to be followed up by VSAVE in order to permanently store the
parameters.
Input format: INIT<CR>
Hex:
49
4E
49
54
0D
ASCII:
‘I’
‘N’
‘I’
’T’
<CR>
Output (example): OK<CR>
Hex:
4F
4B
0D
ASCII:
‘O’
‘K’
<CR>
The following parameters are set:
TOR 50 LRD 01001
MD 2 LNRD 10001
CID 0 LERR 10011
CN 0 LED 1
LSTB 01101 LRT 30
LGT 01111 LPA 00000