Installation
Preparing the wall unit - Extractor version
• The hood is supplied as an
extractor unit.
Before installing the hood, drill a
hole in the roof of the wall unit
(see Fig. 5). This hole is to allow
passage of the outlet pipe and the
power cable, and to facilitate
servicing.
• The wall unit must have a
minimum body depth (without
door) of 300 mm with recessed
light screen and min. 370 mm with
flush-mounted light screen. The unobstructed internal height must
be at least 370 mm.
Outlet hole - (extractor-filter version)
• When used as an extractor unit, the hood must be fitted with a
150mm diameter hose.
Fix the flange on the hood outlet hole, using 2 screws. Fig. 6a.
Filter version only
• Fix the deflector to the flange. Fig. 6b.