Technical Specifications
Dimensions (in cm):
Height 38,7
Width 59,9
Depth 27,5 (+ front panel)
Maximum absorbed power (W): 200
Motor (W): 110
Lighting (W): 2x40
Length of the cable (cm): 150
Electrical connection (V): 220-240
Mounting accessories included
1 allen spanner (for TORX screws)
1 deflector
1 flange
1 reduction flange
2 screws 2,9 x 22 mm (to install the deflector)
4 screws 4,5 x 16 mm (to install the hood in the wall unit)
2 screws 3,5 x 9,5 (to install the charcoal filter frame)
1 screw 2,9 x13 (To fix the flange in place)
1 charcoal filter frame
Electrical connection
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to
any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of
at least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.