DF 6260 Köksfläkt Ventilator Liesituuletin Emhætte Cooker Hood Instruktionsbok Bruksanvisning Käyttöohje Brugsvejledning Operating and Installation Instructions
Contents Safety instructions ............................................................................ Description of the cooker hood .......................................................... Using the cooker hood ...................................................................... Maintenance and cleaning ................................................................. If the cooker hood will not operate ..................................................... Guarantee conditions .....................
Use of cooker hood • This appliance is for domestic use only in a normal household. • Never leave any deep-frying, melting fat, paraffin or any other inflammable liquid unattended on the hob. In the event of fire: Immediately switch off the cooker hood and the cooker. Note! Cover the fire. Never use water. • Never do any flambé cooking underneath the cooker hood. It can cause a fire. Remember that overheated fat may spontaneously ignite. Never leave the frying pan unattended.
Description of the cooker hood Functions There are two possible systems: • Extraction of air to the outside using an optional venting kit and evacuation duct. • Recirculation using an optional charcoal filter. The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed. Fig.
Using the cooker hood The control panel • The switches are arranged on the upper right side of the vapour catcher. (Fig. 1 - E). The numbers and symbols have the following meanings (from left to right): The blower is controlled by shifting the sliding switch. The extractor part (vapour catcher) of the hood is used to switch the blower on and off when the appliance is switched on (Motor).
Maintenance and cleaning Disconnect the cooker hood from the power supply prior to cleaning the appliance, either by removing the plug from the mains or removing the fuse. Clean the filter regularly. The grease deposits in the filter and discharge tube are fire hazards where a hotplate (or another heat source) is left on by error. Cleaning the hood Clean the outside of the hood using a damp cloth and a mild detergent. Never use corrosive, abrasive or flammable cleaning products.
Carbon filter • The activated carbon filter should only be used if you want to use the hood in its filtering function. • To do this you will need an original AEG activated carbon filter (see special accessories). • The carbon filters absorb smells and odours. • Changing and cleaning the carbon filter - KF 8 Unlike other carbon filters, the LONGLIFE carbon filter can be cleaned and reactivated. At normal use the filter should be cleaned every second month.
Changing the light bulb • Disconnect the unit from the mains power supply. • Unlock the lighting cover (D) by twisting the bolts to the left and fold down the bulb cover. Fig. 4. Replace the old light bulb(s) with a new light bulb of the same kind. • Close the bulb cover and relock it by twisting the bolts to the right. • If the light does not come on, make sure the bulb has been inserted in correctly before contacting the technical assistance service. Fig.
If the cooker hood will not operate Check the following prior to calling after sales service: • Has a fuse burnt? Check both fuses and replace if necessary. • Is the power supply plug inserted properly in the power outlet? • Has the flexible tube been mounted correctly? • Is the anti-grease filter clean? • Are the light bulbs intact and soundly fitted? If the problem persists, contact the sales center, the after sales service center or an authorized technician. Only use original spare parts.
European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subject to the following qualifications: The guarantee starts from the date you first purchased your product. The guarantee is for the same period and to the same extent for labour and parts as exists in the new country of use for this brand or range of products. This guarantee relates to you and cannot be transferred to another user.
Special accessories Charcoal KLF 60/80 Charcoal KF 8 E-Nr. 610 899 421 942 120 399 Installation Unpacking Check that the cooker hood is not damaged. Transportation damages should immediately be reported to the transport company. Damages, faults and missing parts should immediately be reported to the retailer. Dispose carefully of the packaging material so that it is out of the way of small children. Position The cooker hood should be mounted freely hanging on the wall.
Installation Preparing the wall unit - Extractor version • The hood is supplied as an extractor unit. Before installing the hood, drill a hole in the roof of the wall unit (see Fig. 5). This hole is to allow passage of the outlet pipe and the power cable, and to facilitate servicing. 190 172 238 Fig. 5 • The wall unit must have a minimum body depth (without door) of 300 mm with recessed light screen and min. 370 mm with flush-mounted light screen. The unobstructed internal height must be at least 370 mm.
Outlet hole (extractor-filter version) • When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. Fix the flange on the hood outlet hole, using 2 screws. Fig. 6a. Filter version only • Fix the deflector to the flange. Fig. 6b. Fig. 6a Fig.
Installing the fume extractor hood in the wall unit - extractor version (Filter version with charcoal filter) • Apply the drilling template to the inside wall of the wall unit on the right and left sides, and mark out and predrill Ø 2 mm mounting holes as well as 2 x Ø 6 mm - 5 mm depth holes for the mounting claws (installation aids). • Fix the flange on the hood outlet hole, using 2 screws. Fig. 6a. • Fully withdraw the vapour catcher of the hood.
• If the cupboard is deeper than 300 mm, cover the gap between the hood and the wall with a finishing strip (special accessory). To install it, proceed as follows: Measure the wall distance and apply the covenng strip over the necessary width (wall distance plus 5 to 8 mm), kinking the covering strip at the appropriate notches and tearing off the surplus material (removing the protective foil). Then fasten the strip to the bottom part of the hood with three clips (special accessories). Apply pressure. Fig.
Removing the hood from the wall unit If, for technical reasons (extractor version/filter version conversion) the fume extractor hood has to be removed from the wall unit, proceed as follows: • Fully withdraw the vapour catcher and remove the grease filter. • Loosen the 4 or 6 mounting screws of the hood (wall unit mounting). • To loosen both mounting claws (installation aids), place a max 3 mm dia.
Installing the front panel (see also “Special accessories”) • Remove first the rear then the front grease filters. • Remove the internal cover pressing both unlocking devices (press and pull). Fig. 12. Fig. 12 • Predrill the front panel as per template and fix it to the vapour catcher with 3 screws. Fig. 13-14. Fig. 13 Fig. 14 • Clip the Internal cover back in and insert both grease filters (first the front one and then the rear one).