Specifications
6
Environmental
Operating Temperature -5 ~40
0
C
Relative Humidity < 95% (Non-Condensing)
Audible Noise <45dBA @ 1 meter
Communication Port Standard RS232; USB or SNMP/HTTP (optional)
* All T2 models have a long standby option with no built in batteries, this is the charge current of the long standby models.
For long standby models, add “-L“ to the part number.
All information contained in this brochure is purely indicative and can not be used to form any contractual obligations.
Specication or design can be changed at anytime without prior notice.
T2 SERIES (1kVA-3kVA)
Launched in 2005 and superseding the highly regarded PHD IP Series UPS, the T2 Series benets
from the latest microprocessor Control Unit (MCU) technology, and now offers even greater value for
money. The T2 is aimed at users that require protection from line voltage uctuations and require a
reliable and constant power source. The T2 is a sophisticated unit utilizing full digital control technology.
Available with power rating of 1kVA, 2kVA and 3kVA each with LCD display and audible alarm keeping
you quickly updated on mains and battery status. The T2 is also tted with an intelligent test button
enabling a self-test routine which also prevents the UPS from being inadvertently switched off.
FEATURES:
• Extensive log les
• Scheduled battery and inverter testing
• Scheduled system shutdown/restart
• User-Customisable commands and messages
• Multiple UPS control from a single computer
• Remote Console Command module for remote multiple server shutdown
• Internal SNMP sub-agent for integration into existing NMS (e.g. HP OpenView, CA).
Model ST2010 ST2020 ST2030
Capacity
Maximum Capacity 1000VA/700W 2000VA/1400W 3000VA/2100W
Input
Input Voltage Range 220/230/240VAC ± 25% Singe Phase w/Ground
Input Frequency 44Hz ~ 56Hz
Output
Output Voltage 220/230/240VAC ± 2%
Output THD < 3%
Efciency (Battery Mode) 82%
Output Frequency (Battery Mode) 50 ± 0.1Hz
Overload Capability (Normal Mode) Sustaining 5 min @ 100 – 200%; 3 sec @ > 200%
Overload Capability (Battery Mode) Sustaining 30 sec @ > 100%; 1 sec @ 150%
Battery
Number of Batteries 2 cells 4 cells 6 cells
Recharge Time to 90% < 8 hours (adjustable)
Charge Current of Long
Standby Model *
5A
Indication
LCD AC Mode, Battery Mode, Output Status, Battery Capacity, Overload, UPS Fault
AudibleAlarm
Battery Mode, Low Battery, Overload Long beeping, Continuous beeping, Short beeping
Physical
W x H x D (mm), Weight 150 x 220 x 460, 19kg 220 x 330 x 487, 32kg 220 x 330 x 487, 42kg
UPS - LINE INTERACTIVE
PURESINEWAVE