Specifications
27
27
T2000 SERIES (20kVA-600kVA)
With many thousands of units sold, the PHD T2000 series UPS
is now legendary. Chosen by major enterprises around the world
for its reliability and performance, words simply can’t explain its
phenomenal success. But we don’t rest on our laurels, the T2000
has been modied and updated and now offers even greater
performance. With a Mean Time Before Failure of power to the
load in excess of 20 years the T2000 is even better value for
money. And with power ratings from 50kVA to 600kVA and higher,
the T2000 is engineered to offer power protection sufcient
to support a whole building if required. And as your power
requirements grow, more T2000 units can be added, offering
superb exibility.
EXPANDABLETOPROTECT
For genuinely redundant power protection, UPS can be installed
in either active parallel or hot standby mode, ready to take
over the load automatically in the event of a critical component
failure. The T2000 can be congured to function in either active
parallel or hot standby mode, with up to 6 units in the array.
In active parallel mode, the load is balanced across all the
congured units, ensuring that no single member of the array is
overstressed. If a unit needs to be shutdown for maintenance or
repair, the remaining units in the array will rebalance the load and
continue to provide uninterrupted protection. It is even possible to
remove a unit from the array during an outage without affecting
the load while the remaining units retain sufcient battery runtime.
In hot-standby mode, one or more units support the load, while
the remaining members of the array functions as standby unit.
The standby unit is continually on-line, but only takes over the
load when one of the primary units is no longer active.
This means that there is no break when power is transferred,
and the load continues to be supported without disturbance.
MANUALANDSTATICBYPASSTOPROTECT
A manual by-pass switch allows power to be transferred directly
to the mains without disturbance to the load. The UPS can then
be safely powered down for maintenance or repair, on completion
of the work the UPS can be powered up and the load once again
transferred back to the UPS with no interruption in service. If
the power demand of your equipment exceeds the overload
level of the UPS the static switch defaults to the mains ensuring
continuous power in the event of system abuse or short term
overload conditions.
TIMETOPROTECT
In addition to providing sufcient run-time to save les and
shutdown operating systems, autonomies of up to 8 hours are
available allowing you the option to complete a day’s work
without disturbance to your equipment, even during a power cut!
UPSMANAGEMENTSOFTWARE
The UPS management software is installed on a server
or workstation connected to each UPS via the serial port.
Power failure, power restored, battery failure or eight events
will be detected and the user informed. A shutdown will be
initiated when the batteries are exhausted or a technical
problem occurswith the UPS. The UPS management software
disconnects network connections, logs out users and closes
open applications (subject to app/os support) before shutting
down the operating system itself.
SIMPLENETWORKMANAGEMENT
PROTOCOL(SNMP)
The T2000 SNMP external agent can be located up to 5
metres away from the UPS. Initial conguration is carried out
by serial comms using any suitable terminal application (e.g.
Hyperterminal for Windows). The embedded HTTP server
presents an HTML interface to the network, which can be
accessed from any web browser. All system parameters
can be congured from here, including scheduled shutdown.
A sophisticated Java applet provides full monitoring in real time,
along with comprehensive event and history logs.
UPS - ONLINE (TRANSFORMER)
3PHASEINPUT,3PHASEOUTPUT