Specifications

19
19
T4 SERIES (10kVA-20kVA)
The T4 is a physically small On-Line UPS but retains all the
features normally associated with double conversion technology.
Simply put "double-conversion" is where the mains supply is
rectied to a DC voltage and rebuilt into a very clean and
regulated AC voltage, at all times your critical load runs
from this clean no break supply.
PARALLEL
A big advantage offered by the T4 10kVA to 20kVA is that by means
of a simple cable the machines can be linked together to form a
parallel N+1 system. This offers the client the opportunity to either
have a fail safe system or the option to expand the power as the
network grows. Up to three machines can be connected in this way
making the T4 a exible and versatile solution.
ULTRACOMPACT
With a very small footprint you will nd a ready home for the T4 in
even the most hard-pressed data center. Installing such a compact
free-standing UPS avoids taking up valuable rack space without
signicantly reducing the available oor area.
DISPLAYPANEL
LCD display and audible alarms actively let you know if the unit
is on battery, the battery charge is low, or there is an overload
condition. Loading and battery information via the LCD prevent
you from exceeding the UPS capacity and allow you to assess
the remaining runtime before battery reserves are depleted.
ADVANCEDBATTERYMANAGEMENT
A variable boost charger ensures quick battery recharge.
This means that the T4 UPS is fully prepared for duty with a
minimum recovery time in the event of a power failure.
Active battery management intelligently monitors the battery
set with automatic battery and circuitry self-tests, this feature
increases both battery life and system reliability.
UPSMANAGEMENT
One standard management tool can be used to monitor and
control all your UPS’s from one central location. This means power
management can now be integrated into your existing network or
building management strategy. Alarms (‘traps’) can be congured
to ensure automatic notication of events such as low battery,
mains failure or overload. Two such tools can be used with the
T4: Simple Network Management Protocol (SNMP) and UPS
Management Software via RS232.
TRUE ON-LINE DOUBLE CONVERSION TECHNOLOGY
FOR ULTIMATE POWER PROTECTION
DSP TECHNOLOGY
PARALLEL REDUNDANCY CAPABILITY AS STANDARD
IGBT INVERTER TECHNOLOGY
SNMP/HTTP OPTION FOR REMOTE MANAGEMENT &
INTEGRATION INTO NMS
SMART RS232 AS STANDARD
INTEGRATED SMARTCARD SLOT PROVIDING A CHOICE
OF COMMUNICATIONS INTERFACES
OPTIONAL SPECIALISED UPS MANGEMENT SOFTWARE
USER FRIENDLY LCD DISPLAY
FAILSAFE INTERNAL BYPASS SWITCH WITH MANUAL
CONTROL
LONG RUNTIME AVAILABILITY.
UPS - ONLINE (TRANSFORMERLESS)
3PHASEINPUT,1PHASEOUTPUT