POWER MANAGEMENT
LED INDICATOR (POWER MANAGEMENT ACTIVE)
The power management feature is comprised of two stages : On or Out
Of Range (Green), Off (Green blinking).
In the off mode, all circuitry in the monitor is shut down, except for a low
power detection circuit. This circuit allows the monitor to wake up when
the mouse is moved or a key on the keyboard is pressed.
Power Mode
Normal
Out Of Range
Off
Off
Off
Pulse
Pulse
Pulse
No Pulse
No Pulse
Pulse
Pulse
No Pulse
Pulse
No Pulse
Active
Active
Blanked
Blanked
Blanked
Green
Green
Green blinked per 1 second
Green blinked per 1 second
Green blinked per 1 second
H-Sync V-Sync Video LED Color