21. USING THE EXTRACARE FUNCTION
Extracare intercom units are available for certain categories of schemes where alarm calls must be
cancelled at the source of the call. Systems can contain a mixture of standard and Extracare intercoms
to maximise operational efficiency whilst ensuring care level compliance.
When a call is made from an Extracare intercom it is reported and answered in the normal way but it
cannot be permanently cleared until it has been visited and cancelled locally. If normal cancellation is
attempted the call will simply re-report after a preset delay (typically 5 minutes).
The LED indicator will flash red on an
Extracare intercom awaiting cancellation.
Pass the magnetic reset fob down the right
hand side of the intercom to be cancelled.
The intercom will emit several short beeps
and the LED will extinguish when the
call is cancelled.
IMPORTANT
A procedure must be put in place for the cancellation of extracare intercoms when the system is
operating in Local or Remote Offsite modes.
22. CALLER ID DISPLAY PANEL
The Advent xt Caller ID Display Panel is a large wall mounted 4 digit LED display which will show the
identity of the call in progress during all operating modes.
Up to 16 Caller ID Display Panels may be installed throughout the site. In addition to flat numbers any
system faults will be displayed as a 4 digit code, see table above.
15 September 2009 FM0420 issue D Page 13
tynetec
#
*
Fire Alarm
3999
Daily Alarm
4785
Door Panel Fault
4828-4843
Status Module Fault
4824-4827
PBX Interface Fault
4816-4823
Network Receiver Fault
4800-4815
Low Battery
4793
12V/24V Fuse Blown
4794
BT Line Restored
4796
BT Line Failure
4797
Mains Restored
4798
Mains Failure
4799
FAULTCODE