User Guide

2
J8
WARNING!
Electrical shock hazard present
during telephone line servicing.
5
3
2
1
6
7
8
4
5
3
2
1
6
7
8
4
"Primary" Dial Line
Connection
"Secondary" Dial Line
Connection
RING TIP
RING
TIP
DEDT
DEDR
------
------
------
------
------
EGND
------
XF2
DUPO
ANS
TLM
------
------
+12V
------
90227
SN:
TELPLUS
REV
DED
DIAL
Base Module
JP1
JP2
JP3
JP4
NOTE: All UL Fire and Burglary installations
must use the fused RJ31X jack included
in the ULB and ULF Installation Kits.
EGND Cable to chassis EARTH GND stud
To Dial
Telco Line
To Primary
House Phone
To Dial
Telco Line
To Secondary
House Phone
Figure 1. TelPlus Secondary Dial Line Configuration
PRIMARY DEDICATED LINE INSTALLATION
The required RJ cord and external RJ31X jack are supplied in the
installation kit. Refer to Figure 2 throughout the installation and
setup procedure.
1. Install the external RJ31X jack in a location near the Advan-
tage plus chassis. Be sure to label the dedicated line RJ31X
jack so a dial line is not plugged here by mistake.
UL Fire and Burglary installations must use the fused RJ31X
jack included in the ULB and ULF Installation Kits.
2. Connect the dedicated line to pins 4 and 5 of the external RJ
jack.
NOTE: Local codes and/or ordinances may require that your
local telephone company make these connections.
J8
WARNING!
Electrical shock hazard present
during telephone line servicing.
5
3
2
1
6
7
8
4
5
3
2
1
6
7
8
4
"Backup" Dial Line
Connection
"Primary" Dedicated
Line Connection
RING TIP
RING
TIP
DEDT
DEDR
------
------
------
------
------
EGND
------
XF2
DUPO
ANS
TLM
------
------
+12V
------
90227
SN:
TELPLUS
REV
DED
DIAL
Base Module
JP1
JP2
JP3
JP4
NOTE: All UL Fire and Burglary installations
must use the fused RJ31X jack included
in the ULB and ULF Installation Kits.
EGND Cable to chassis EARTH GND stud
To Dial
Telco Line
To House
Telephone
To Dedicated
Line
Figure 2. TelPlus Primary Dedicated Line Configuration
3. MAKE SURE TelPlus DED jumpers JP3 and JP4 are installed,
and jumpers JP1 and JP2 are removed. This configures the
TelPlus for primary dedicated line operation.
4. Plug the RJ cord into the external jack, route into the chassis, and
plug the other end to the TelPlus RJ jack (J2).
NOTE: Wire the Base Module backup dial line identically to a
Base Module primary dial line. OPTIONS DOWN-
LOADING WITH TELPLUS
When using the TelPlus for dedicated line connection, always
disconnect the dedicated line for the Base Module’s initial options
download. While in the Test Mode, the Base Module always
assumes it is configured for dial line operation.
TELPLUS OPERATION
In Dial Line #2 operation, TelPlus relay K1 is turned on, connecting
the TelPlus to the dial line through JP 1 and 2.
In dedicated line operation, TelPlus relay K1 turns off, connecting
the TelPlus to the dedicated line through JP 3 and 4. If the dial
backup on the Base Module is needed, relay K1 turns on.
DIALING SEQUENCE
Adding the TelPlus as a secondary dial telephone line provides
the Advantage plus with three different dialing options. All three
of the available options use a dual line dialing sequence to dial
the two programmed central station telephone numbers:
Sequence A. 1, 2, 1, 2, 1, 2, 1, 2
Sequence B. 1, 1, 2, 2, 1, 1, 2, 2
Sequence C. 1, 1, 1, 1, 2, 2, 2, 2
Using Sequence A, the primary line always dials the first pro-
grammed telephone number, and the secondary (TelPlus) line always
dials the second programmed telephone number.
The other two sequences are useful when using cellular for the
secondary (backup) line. All dialing sequences try to report using the
land line first if possible.
LINE MONITORING
Selecting the Enable Line #2 Monitor option allows the TelPlus to
generate an alarm any time the DC voltage on dial line #2 falls below
2 VDC for over one minute.
For UL Fire systems you must enable both the primary and second
dial line Telephone Line Monitors. This ensures that if one line goes
down that Advantage plus only attempts communication over the
existing good line.
NOTE: Enabling Telephone Line Monitor #2 automatically
dedicates the Base Module’s AUX4 output for telephone
line monitoring, making it unavailable for other uses.
CONTACT CHECKS
Optioning a dual dial telephone line system for Contact Check at
exactly 24 hours automatically performs the contact check on both
lines.
Advantage plus first calls the central station using the primary
line, then the secondary line. This verifies that both lines are
functioning properly.
NOTE: The times that the system performs the contact checks
depends upon the account number. All 24-Hour contact
checks are performed at low traffic times, between 11 PM
and 5 AM.