User Guide
9
Figure 7. Advantage plus Installation Diagram (Sheet 1 of 2)
NO
COM
NC
GND
+12V
AUD
J1
J2
SENS
AC
16.5V
J1
POWER
BELL
+ -
+12 GND
-AS
-AS
AU-
AU+
AU-
AU+
AU-
AU+
AU-
AU+
+AS
+AS
+12
AX1-
+12
AX2-
+12
AX3-
+12
AX4-
DAT2
- +
DAT1
- +
J2
J3
AUDIO
AX
MOD
J4
- +
A10
GND
GND
+5V
CR0
CR1
- +
A11
- +
A12
- +
A13
- +
A14
- +
A15
- +
A16
- +
A1
- +
A2
- +
A3
- +
A4
- +
A5
- +
A6
- +
A7
- +
A8
- +
A9
S1
OPER
TEST
A8
A7
A6
A5
A4
A3
A2
A1
A16
J5
LOOPS
GND
LOOPS
J6
A15 A14 A13 A12 A11 A10 A9
RESET
AUDIO
-------
+12V
GSTART
AGND
+5V
+5VSTB
LAUD
-------
RING
TIP
DEDT
DEDR
----
----
----
----
----
EGND
----
XF2
DUPO
ANS
TLM
----
----
+12V
----
GND
J9
RING TIP
J8
J7
TEST PTS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Transformer:
Input-120VAC, .31A
Output-16.5 VAC, 50VA
(Supervised)
CAUTION!
Incorrect wiring may result
in damage to the unit!
WARNING!
Electrical shock hazard present
during telephone line servicing.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SENS
TMP
TMP
TEST
GND
+12V
AUD
J1
AudioSensor
Advantage plus Installation Diagram
11/10/97
BLK
BLK
GRN
GRN
RED
RED
Reader
LED
5
3
2
1
6
7
8
4
5
3
2
1
6
7
8
4
Dial Telephone Line
Connection
Dedicated Line
Connection
18AWG, 2-Conductor Cable
(15 feet maximum)
BAT
- +
+
(Supv.)
+
(Supv.)
6
5
4
3
2
1
NOTE: All UL Fire and Burglary installations
must use the fused RJ31X jack included
in the ULB and ULF Installation Kits.
GND
GND
GND
WARNING!
DO NOT connect the
transformer to a
receptacle controlled by
a switch!
+
Supervised
GBD-S
1
2
3
4
5
6
7
8
9
10
11
12
13
UL Certificated Fire systems shall be installed
in accordance with Chapter 2 of the National
Fire Alarm Code, ANSI/NFPA 72-1993.
NOTE:
Battery Charging :
400mA max., 10mA min., 12V, 7AH
Sealed Lead-Acid Batteries,
estimated life 3 years.
Ground and Power from
Base Module J4 pins 11
and 12 respectively.
RED
BLK
1KEOL
1KEOL
DS
EOL-200
BRN
BRN
Automatic, Manual,
Sprinkler Supervisory or
Waterflow Devices.
See Sheet 2 for
Supervised Fire
Annunciator Wiring
Listed
4-Wire Smoke
Detectors
(Style B)
Recommended Fire Initiating
Loop Connection
Enclosure
Tamper
Switch
LCD/LCD plus Keypad Power Rating:
9-15VDC, 45mA, 5 Ohms maximum
Line Resistance
(Keypad Must Be Supervised)
1K
Ohm
N/O Loop
1K
Ohm
N/C Loop
Alarm Loop Power Rating :
5V, 5mA, 470 Ohms maximum
line resistance
Auxiliary Output Power Rating :
9.7-12VDC, 100mA each
maximum
Bell Power Rating :
9.2-12VDC, 1.5 A maximum
RS-485 data to optional Expansion Modules,
SmartAudio Modules, ListenIn Modules,
Access Modules, Wireless Module* and LCD
plus keypads. (* not UL Listed)
Card Reader
(optional)
Earth
Ground
To Dial
Telco Line
To House
Telephone
To
Dedicated
Line
To Base
Module J8
RJ Jack
No Connection
UL LISTED POWER LIMITED CIRCUITS:
1. J2-11,12 Local Bell
2. A1 through A16 Alarm Loops
3. AX1- through AX4- Auxiliary Outputs
4. J3-1 & 2 and 11 & 12 Audio Sensor connections
5. J1-1 through 4 and J1-6 through 9 Voltage Out
COMPATIBLE UL LISTED SENSORS & DEVICES:
Detection Systems, DS200-4W (Smoke Detector)
Detection Systems, DS200HD-4W (Smoke Detector)
Detection Systems, MB4W (Smoke Detector)
Detection Systems, MB4WA (Smoke Detector)
Detection Systems, MB4WE (Smoke Detector)
Detection Systems, MB4WS (Smoke Detector)
Detection Systems, EOL200 (End of Line Module)
Wheelock CH-BF, CH-CF2, CH-DF2
Wheelock LS1M-12VFR, LSP-12-HFR
Wheelock LS1M-12-VFR, LSPM-12-VFR
Wheelock MB-G6-12-R
Wheelock MMB-G10-12-W-HFR-R
Wheelock MS1-12-VFR, MSP-12-HFR
Wheelock MT12/24R, MT4-12/24-R
Wheelock MT-12-LS-VFR, MT4-LS-VFR
Wheelock MT-12-LSM-VFR, MT4-LSM-VFR
Wheelock MT-12-MS-VFR, MT4-12-MS-VFR
Wheelock MIZ-12-R, MIZ-12-W
Wheelock MIZ-12-LS-VFR
Wheelock MIZ-12-LSM-VFR
Wheelock MIZ-12-MS-VFR
Wheelock AS-1215-VFR
Wheelock AS-121575-VFR
Wheelock AS-1230-VFR
Wheelock AH-12-R
Wheelock SM-12/24-R and DSM-12/24-R
TELEPHONE LINE:
Voice Grade - 300-3300HZ, 16dB loss (typical)
TERMINATIONS:
Use Panduit tool number MCT-100F for all Panduit
connections.
Use UL Recognized limited energy copper cables for all
terminations.
Advantage GlassBreak (GBD-S) Power Rating:
+12VDC, 26mA, 100 Ohms max. Line Resistance
Composite audio from optional SmartAudio
Module and/or ListenIn Module audio outputs
Advantage AudioSensor Power Rating:
+12VDC, 5mA, 100 Ohms max. Line Resistance
BEEPOUT
GND
DATA-
DATA+
+12VIN
1248
ADDRESS
JUMPERS