Cellular Module
The Cellular Module allows the Advantage
®
plus Base Module to communicate with
the monitoring console via cellular communications. This can be used to provide
security in situations where phone lines are unavailable, or to provide backup
communication if regular phone service is interrupted.
Dimensions
PCB Foot Print
11.00" W x 8.0" H (27.94cm x 20.32cm)
Cellular Interface
Motorola 3 watt, full duplex unit
Communication with cell constantly monitored
Cable length to antenna is 15 feet
Operating Environment
0° F to 122° F (0° C to 50° C)
Power Requirements
12 VDC from Base Module backup battery(s)
100mA in Normal Standby mode
1,600 mA in transmit mode
Mounting
Mounts locally inside Base Module enclosure
Part Numbers
CELLULAR MODULE Cellular Module Complete with
Installation Kit
APS12V1A-S Power Supply, 12VDC
09820457 Cellular Module Installation
Instructions
90194102 PCB, Cellular Interface to Base
Module
AVRPLUSBASCELKT Factory integrated Base
Module and Cellular Module,
assembled in attack enclosure,
with 120 VAC internal
transformer. Includes AC “Level
2” surge protection and dial
phone line “Level 2” surge
protection
AVR PLUSCELLKT Factory integrated Base Module,
Cellular Module, and SmartAudio
Module, assembled in attack
enclosure, with 120 VAC internal
transformer. Includes AC “Level
2” surge protection and dial
phone line “Level 2” surge
protection