User Guide
6101 Lake Ellenor Drive • Orlando, Florida 32809
Tel: 800/ADVANTOR • 407/859.3350 • Fax: 407/859.5205
http://www.advantor.com
Specifications and part numbers are subject to change without notice.
Part Numbers
ACCESS 4-A Complete Access Kit, standard
enclosure, plug-in transformer
ACCESS 4-A KIT Complete Access Kit, standard
enclosure with internal trans-
former(120VAC), and AC “Level
2” Surge Protection
INT ACCESS 4-A Complete Access Kit, 220VAC,
standard enclosure, internal
transformer
INT ACC-4-AT Complete Access Kit, 220VAC,
attack enclosure, internal
transformer, and AC “Level 2”
Surge Protection
90212153 PCB, Access Module
90237200 Standard Enclosure with Lock
and Key
90258200 Attack Enclosure with Lock and
Key
08610416 Transformer, 16.5VAC, 50VA,
Plug-In
09820451 Access Module Installation
Instructions
RMOD-A Relay Module for 8 additional
relay outputs
08061699 AC Surge Protector (120VAC),
hardwired
08061431 AC Surge Protector (220VAC),
hardwired
08061206 Battery, 12V, 7AH, Gel Cell
Secondary Power
• Two, 12 VDC, 7 AH, sealed lead-acid rechargeable
batteries
• Internal battery charger
• Backup capabilities 2 to 6 hours typical (depending
upon equipment)
Auxiliary Power
• 12 VDC at 0.9 Amps continuous for external
equipment
• 12 VDC at 1.0 Amp for door locks
Communications
Access Module RS-485 Port
• Communication link: 2,000 feet maximum with
22AWG shielded twisted pair cable
• Supports a maximum of 40 optional RS-485 devices
Approvals
• FCC Part 15, Class B, Part 68
• UL 294, “Access Control System Units”