User Guide
6101 Lake Ellenor Drive • Orlando, Florida 32809
Tel: 800/ADVANTOR • 407/859.3350 • Fax: 407/859.5205
http://www.advantor.com
Specifications and part numbers are subject to change without notice.
Access Module
The Access Module adds access control to the Advantage
®
plus system. Each Base
Module can interface and control up to seven Access Modules with each module
controlling four card readers.
General Features
• Access for up to 10,000 cardholders, with 256 Access
Levels
• 128 programmable Time Shifts & Time Periods per
property
• Optional Anti-Passback, either local or global
• Programmable outputs to control equipment, such as
HVAC and lighting
• Distributed Processing system with 8,000 event local
buffer memory
• Optional Free Exit or Card Controlled exit
• Compatible with most card types
• Weigand
• Proximity
• Magnetic stripe
• Bar Code
• Level 1 (card only); Level 2 (card plus PIN) or Level 3
(card, PIN and biometrics) capability.
Dimensions
Standard UL Enclosure
• 17.25” W x 14.5” H x 3.25” D ( 43.82cm x 36.83cm x
8.26cm)
• 20 gauge cold rolled steel with lock and key
• Color: Light gray w/ Advantor logo
Attack-Rated UL Enclosure
• 17.25” W x 14.5” H x 3.25” D ( 43.82cm x 36.83cm x
8.26cm)
• 18 gauge cold rolled steel with lock and key
• Color: Light gray w/ Advantor logo
PCB Foot Print
• 12.75" W x 8.75" H (32.39cm x 22.23cm)
Alarm Points
• 14 programmable, supervised, hard-wired points
• N/C, N/O, or Both (dry contacts)
• Four programmable door inputs
• 10 programmable, general purpose, alarm inputs
• One tamper input (alarm-on-open only)
• One global free-exit input (for fire evacuation)
• Programmable alarm codes
• Assignable to any of eight separate arming
partitions (protected areas)
Operating Environment
• 0° F to 122° F (-18° C to 50° C)
Auxiliary Outputs
• Six, 100mA, programmable hard-wired
• One auxiliary output per controlled door (four total)
• Two auxiliary outputs for general control
• Optional RMOD (Relay Module)
• 4 RMODS per Access Module
• 8 relays per RMOD
• Controlled by shift or user groups
Primary Power
• 100 to 120 VAC, 60Hz, using 16.5 VAC, 50VA, Class
2 plug-in transformer
• 100 to 120 VAC, 50-60Hz with enclosure mounted
transformer
• 200 to 240 VAC, 50-60Hz with enclosure mounted
transformer
• Optional AC “Level 2” Surge Protection
P/N 09820482, Rev. A