User Manual WISE-4000 Series IoT Ethernet I/O Module
Copyright The documentation and the software included with this product are copyrighted 2015 by Advantech Co., Ltd. All rights are reserved. Advantech Co., Ltd. reserves the right to make improvements in the products described in this manual at any time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any form or by any means without the prior written permission of Advantech Co., Ltd. Information provided in this manual is intended to be accurate and reliable.
Declaration of Conformity CE This product has passed the CE test for environmental specifications. We recommend the use of shielded cables. . Technical Support and Assistance 1. 2. Visit the Advantech web site at www.advantech.com/support where you can find the latest information about the product. Contact your distributor, sales representative, or Advantech's customer service center for technical support if you need additional assistance.
3. Disconnect this equipment from any AC outlet before cleaning. Use a damp cloth. Do not use liquid or spray detergents for cleaning. 4. For plug-in equipment, the power outlet socket must be located near the equipment and must be easily accessible. 5. Keep this equipment away from humidity. 6. Put this equipment on a reliable surface during installation. Dropping it or letting it fall may cause damage. 7. The openings on the enclosure are for air convection. Protect the equipment from overheating.
Contents Chapter 1 Product Overview ................................1 1.1 1.2 1.5 1.6 1.7 1.8 Introduction ............................................................................................... 2 Feature Highlights ..................................................................................... 2 1.2.1 RESTful Web Service ................................................................... 2 1.2.2 Data Storage Function .................................................................. 3 1.
2.6 2.7 Chapter 3 Hardware Installation........................ 31 3.1 3.2 Interface Introduction .............................................................................. 32 Mounting ................................................................................................. 32 3.2.1 DIN-Rail Mounting ...................................................................... 32 Figure 3.1 Mounting Kit Back View............................................ 32 Figure 3.
4.3 4.4 4.2.4 Module Authorization .................................................................. 41 4.2.5 Operation Mode .......................................................................... 41 4.2.6 Using a Browser to Configure the Module ................................. 42 4.2.7 Configuring Cloud Server (WISE-4000 wireless series only)...... 58 Configure WISE-4000 with ADAM.NET Utility ........................................ 61 4.3.1 Operation Framework ......................................
WISE-4000 User Manual viii
Chapter 1 Product Overview 1
1.1 Introduction WISE-4000 series is an Ethernet-based wired or wireless IoT device, which integrated with IoT data acquisition, processing, and publishing functions. Except various I/O type offering, WISE-4000 series provides data pre-scaling, data logic, and data logger functions. These data can be access via mobile devices and be published to cloud with security in anytime and anywhere. 1.2 Feature Highlights 1.2.
The internal flash of the WISE module can log up to 10,000 data samples with a time stamp. The I/O data can be logged periodically, and when the I/O status changes. Once the memory is full, users can choose to overwrite the old data to ring log or just stop the log function. When the module is powered-off, data can be kept in the module. When restarting, users can decide whether to clear all data or continue logging. 1.2.
1.3 Series Family and Specifications 1.3.
1.4.1 WISE-4000 Wireless Series Dimensions Chapter 1 1.4 Mechanical Design and Dimensions Product Overview 1.4.
1.
Chapter 1 1.
1.
Chapter 2 2 Product Specifications
2.1 General Specification WLAN Interface Standard Conformance: – 802.11b – 802.11g – 802.11n (2.4GHz only) Network Modes: – Limited AP (Wireless Server) – Station/Infrastructure (Wireless Client) LAN Interface Ethernet: IEEE 802.3u 10/100Base-T(X) Connector: 1-port RJ-45 General I/O Connector: 3.5mm spacing, 15-pole, plug-in screw terminal block Power Connector: Micro-B USB for WISE-4012E, other modules use same connector as I/O Watchdog Timer – System: 1.
Chapter 2 Power Power Input Voltage: 10~30 VDC (24 VDC Standard) – WISE-4050 – WISE-4060 – WISE-4010/LAN – WISE-4050/LAN – WISE-4060/LAN USB 5VDC – WISE-4050: 2.2 W @ 24 VDC – WISE-4060: 2.5 W @ 24 VDC – WISE-4010/LAN: 1.2 W @ 24 VDC – WISE-4050/LAN: 2.2 W @ 24 VDC – WISE-4060/LAN: 2.5 W @ 24 VDC Reverse Power Protection (not for WISE-4012E) Software Configuration Interface: Web Interface, Windows Utility Utility: WISE-4000/Apax .NET Utility Driver: WISE-4000 .
2.2 WISE-4010/LAN 2.2.1 I/O Specification Current Input – Channel: 4 – Resolution: 12-bit – Sampling Rate: 10/100 Hz/channel – Accuracy: ±0.2% of FSR @ 25°C – Input Range: 0~20 mA, 4~20 mA (Select by Web Configuration) – Input Impedance: 120 Ω – Burn-out Detection: Yes (4~20 mA only) – Supports Data Scaling and Averaging Digital Output – Channels: 4 –Open collector to 30 V, 500 mA max.
Chapter 2 2.2.2 Application Wiring Figure 2.2 WISE-4010/LAN Digital Output Wiring Diagram 13 WISE-4000 User Manual Product Specifications Figure 2.
2.2.3 Pin Assignment Figure 2.3 WISE-4010/LAN Pin Assignment 2.2.4 Block Diagram Figure 2.4 WISE-4010/LAN Block Diagram 2.3 WISE-4050/LAN 2.3.1 I/O Specification Digital Input – Channel: 4 – Logic level –Dry Contact 0: Open 1: Close to DI COM –Wet Contact 0: 0~3 VDC or -3~0 VDC 1: 10~30 VDC or -30~-10 VDC (3 mA min.
– On Resistance (RDS(ON)): 0.7 Ω (max.) @ 500mA, 25°C Product Specifications – Supports 1 kHz Pulse Output – Supports High-to-Low and Low-to-High Delay Output 2.3.2 Application Wiring Figure 2.5 WISE-4050/LAN Digital Input Wiring Diagram Figure 2.6 WISE-4050/LAN Digital Output Wiring Diagram 15 Chapter 2 Digital Output – Channels: 4 – Open collector to 30 V, 500 mA max.
2.3.3 Pin Assignment Figure 2.7 WISE-4050/LAN Pin Assignment 2.3.4 Block Diagram Figure 2.
2.4.1 I/O Specification – Isolation: 3,000 Vrms – – – – Supports 32-bit Counter Input Function (Maximum signal frequency 3 kHz) Keep/Discard Counter Value when Power-off Supports Frequency Input Function (Maximum frequency 3 kHz) Supports Inverted DI Status Relay Output – Channels: 4 (Form A) – Contact Rating (Resistive Load) –250 VAC @ 5 A –30 VDC @ 3 A – Relay On Time: 10 ms – Relay Off Time: 5 ms – Insulation Resistance: 1 GΩ min.
2.4.2 Application Wiring Figure 2.9 WISE-4060/LAN Digital Input Wiring Diagram Figure 2.
Chapter 2 2.4.3 Pin Assignment Figure 2.11 WISE-4060/LAN Pin Assignment Product Specifications 2.4.4 Block Diagram Figure 2.
2.5 WISE-4012E 2.5.1 I/O Specification Voltage Input – Channel: 2 – Resolution: 12-bit – Sampling Rate: 10 Hz (Total) – Accuracy: ±0.
The analog input channel of the WISE-4012E does not support inverted voltage protection, note that the input voltage should within 0~10VDC Chapter 2 Note! Product Specifications 21 WISE-4000 User Manual
2.5.2 Application Wiring Figure 2.13 WISE-4012E Voltage Input Wiring Diagram Figure 2.14 WISE-4012E Digital Input Wiring Diagram Figure 2.
Chapter 2 2.5.3 Pin Assignment Figure 2.16 WISE-4012E Pin Assignment Product Specifications 2.5.4 Block Diagram Figure 2.
2.6 WISE-4050 2.6.1 I/O Specification Digital Input – Channel: 4 – Logic level –Dry Contact 0: Open 1: Close to DI COM –Wet Contact 0: 0~3 VDC 1: 10~30 VDC (3 mA min.
Chapter 2 2.6.2 Application Wiring Figure 2.19 WISE-4050 Digital Output Wiring Diagram 2.6.3 Pin Assignment Figure 2.20 WISE-4050 Pin Assignment 25 WISE-4000 User Manual Product Specifications Figure 2.
2.6.4 Block Diagram Figure 2.
Chapter 2 2.7 WISE-4060 2.7.1 I/O Specification – Isolation: 3,000 Vrms – Supports 32-bit Counter Input Function (Maximum signal frequency 3 kHz) – Keep/Discard Counter Value when Power-off – Supports Frequency Input Function (Maximum frequency 3 kHz) – Supports Inverted DI Status Relay Output – Channels: 4 (Form A) – Contact Rating (Resistive Load) –250 VAC @ 5 A –30 VDC @ 3 A – Relay On Time: 10 ms – Relay Off Time: 5 ms – Insulation Resistance: 1 GΩ min.
2.7.2 Application Wiring Figure 2.22 WISE-4060 Digital Input Wiring Diagram Figure 2.23 WISE-4060 Relay Output Wiring Diagram 2.7.3 Pin Assignment Figure 2.
Chapter 2 2.7.4 Block Diagram 29 WISE-4000 User Manual Product Specifications Figure 2.
WISE-4000 User Manual 30
Chapter 3 3 Hardware Installation
3.1 Interface Introduction 3.2 Mounting WISE-4000 modules are designed as compact units and are allowed to be installed in the field site under the following methods. 3.2.1 DIN-Rail Mounting The WISE-4000 module can also be fixed to the cabinet by using mounting rails. You need to assemble the DIN rail adapter to WISE-4000 module with flathead screw driver as below.
Chapter 3 Hardware Installation Figure 3.3 Mounting on the DIN-Rail Figure 3.
3.2.2 Wall Mounting Each WISE-4000 module is packed with a plastic wall mounting bracket. User can refer the bracket dimension and assembling figure to configure an optimal placement in a wall, panel, or cabinet. Figure 3.
Chapter 3 Hardware Installation Figure 3.6 Wall Mounting Figure 3.
3.2.3 Stack Mounting Figure 3.8 Stack Mounting Figure 3.
This section introduces basic information on wiring the power supply, I/O units, and Ethernet connection. 3.3.1 Power Supply Wiring (Not for WISE-4012E) Screw terminals +Vs and -Vs are for power supply wiring Figure 3.10 Power Supply Wiring Note! The wires used should be at least 2 mm. 3.3.2 USB Power (WISE-4012E Only) The system of WISE-4012E IoT Developer Kit is designed for a standard Micro-B USB 5VDC power supply. Use the provided USB power cable to power up the module.
Figure 3.11 USB Power Supply Wiring 3.3.3 I/O Units The system uses a plug-in screw terminal block for the interface between I/O modules and field devices. The following information must be considered when connecting electrical devices to I/O modules. 1. The terminal block accepts wires from 0.5 mm to 2.5 mm. 2. Always use a continuous length of wire. Do not combine wires. 3. Use the shortest possible wire length. 4. Use wire trays for routing where possible. 5. Avoid running wires near high-energy wiring.
Chapter 4 4 System Configuration
4.1 Connection 1. 2. 3. Plug a DC power source into the +Vs, -Vs pin of WISE module to turn the power on, or plug in the USB power cable for the WISE-4012E. For WISE-4000/LAN Series, connect your computer to Ethernet port of WISE module with RJ-45 cross-over Ethernet cable, and configure the IP address of your computer as same IP domain as default IP address of module: 10.0.0.1. Or the wireless router can be used for configure the WISE-4000/LAN Series by mobile devices or computer with wireless adapter.
List of WISE-4000 Default Ethernet Ports Application Protocol Port Note WebServer TCP 80 Configurable Modbus Server TCP 502 - Search Engine UDP 5048 - SNTP Client UDP - Randomly Chapter 4 4.2.2 System Configuration 4.2.3 Factory Default Settings WISE-4000/LAN Series Operation Mode: Normal Mode IP Mode: Static IP Address Default IP: 10.0.0.1 Subnet Mask: 255.0.0.0 Default Gateway: 0.0.0.
4.2.6 Using a Browser to Configure the Module Configure URL: http://IP_address/config Default URL: WISE-4000/LAN Series: http://10.0.0.1/config WISE-4000 Wireless Series: http://192.168.1.1/config Configuration Steps Login Web Configuration Page 1. 2. 3. 4. WISE-4000 User Manual Wirelessly connect your smart phone to your local Ethernet network and open the browser of your smart phone. Enter IP address of module with "/ config", for example, the default URL: http://10.0.0.