25 WISE-2834 User Manual
Chapter 4 System Configuration
4.3 RFID Antenna setting
4.3.1 RFID region setting
The region can be set according to the country of the end user
4.3.2 RFID Antenna Configuration
The channel needs to enable according to the antenna installation
The power level range is related to the country setting
For example: country region is set as US/CA/MX, the range of power lever is
between 10~31.5 dBm
Maximum Dwell Time: Specifies the max amount of time in ms that may be
spent on the logical antenna port during a tag-protocol-operation cycle before
switching to the next enabled antenna port
Maximum Inventory Cycles: Specifies the max number of inventory cycles to
attempt on the antenna port during a tag-protocol-operation cycle before switch-
ing to the next enabled antenna port
Stop reading condition: The condition when the antenna should stop reading
tags
Maximum dwell time (ms)
Maximum inventory cycles
Reader will stop reading tag value if meet 1 of above 2 stop conditions