User's Manual
Table Of Contents
- WISE-2834
- 1 Product Overview
- 2 Product Specification
- 3 Mechanical and Hardware Installation
- 4 System Configuration
- 5 Software Programming (Node- RED)
- 5.1 Terminology Definition
- 5.2 System Architecture
- 5.3 Graphic programming with Node-RED
- 5.3.1 Node-RED page
- 5.3.2 Tag Inventory
- 5.3.3 Tag Read
- 5.3.4 Tag Write
- 5.3.5 Tag Lock
- 5.3.6 Tag Kill
- 5.3.7 Tag Access Results
- 5.3.8 Get DIO value
- 5.3.9 Get counter value
- 5.3.10 Get counter status
- 5.3.11 Get DO pulse count and continue mode
- 5.3.12 Get latch status
- 5.3.13 Set DO value
- 5.3.14 Set counter value
- 5.3.15 Set DO pulse
- 5.3.16 Clear latch
- 5.4 API for Development
- A RFID node output
- B RFID module error code
- C RFID Frequency Channel Tables
- C.1 United States/Canada/Mexico Region Frequency Channel Table
- C.2 Europe Region Frequency Channel Table (ETSI EN 302 208)
- C.3 Europe2 Region Frequency Channel Table(ETSI EN 300 220)
- C.4 Taiwan Region Frequency Channel Table
- C.5 China Region Frequency Channel Table
- C.6 South Korea Region Frequency Channel Table
- C.7 Australia/New Zealand Region Frequency Channel Table
- C.8 Brazil Region Frequency Channel Table
- C.9 Israel Region Frequency Channel Table
- C.10 India Region Frequency Channel Table
- C.11 Japan Region Frequency Channel Table
- C.12 Japan2 Region Frequency Channel Table (with LBT)
25 WISE-2834 User Manual
Chapter 4 System Configuration
4.3 RFID Antenna setting
4.3.1 RFID region setting
The region can be set according to the country of the end user
4.3.2 RFID Antenna Configuration
The channel needs to enable according to the antenna installation
The power level range is related to the country setting
– For example: country region is set as US/CA/MX, the range of power lever is
between 10~31.5 dBm
Maximum Dwell Time: Specifies the max amount of time in ms that may be
spent on the logical antenna port during a tag-protocol-operation cycle before
switching to the next enabled antenna port
Maximum Inventory Cycles: Specifies the max number of inventory cycles to
attempt on the antenna port during a tag-protocol-operation cycle before switch-
ing to the next enabled antenna port
Stop reading condition: The condition when the antenna should stop reading
tags
– Maximum dwell time (ms)
– Maximum inventory cycles
– Reader will stop reading tag value if meet 1 of above 2 stop conditions