2.5.4 Terminal Resistor (JP9~JP16)
The onboard termination resistor (120 ohm) for COM3~COM10 can be
used for long distance transmission or device matching. (Default Open.)
Please also refer to Table 2.9 for the mapping table of Jumper and COM
port.
Table 2.8: Jumper setting of terminal resistor
JPx Description
Add termial resistor on Tx+/Tx- of RS-422 or Data+/Data-
of RS-485
Add termial resistor on Rx+/Rx- of RS-422
Table 2.9: Mapping table of Jumper/DIP for COM port
COM port Jumper for RS-232
and RS-422/485
selection
SW2 DIP switch
for Auto-flow
control
Jumper for
Terminal
Resistor
COM3 JP2 DIP1 JP10
COM4 JP3 DIP2 JP11
COM5 JP1 DIP3 JP9
COM6 JP4 DIP4 JP12
COM7 JP6 DIP5 JP14
COM8 JP7 DIP6 JP15
COM9 JP5 DIP7 JP13
COM10 JP8 DIP8 JP16