User's Manual
Table Of Contents
- Chapter 1 General Information
- Chapter 2 System Setup
- Chapter 3 System Tuning
- Chapter 4 Windows CE .NET 4.2
- Figure 4.1: Windows CE on TPC-60S
- 4.1 TPC Utilities
- 4.2 Networking
- 4.2.1 Network via Ethernet
- 4.2.2 Network via Serial Port
- Figure 4.24: PC Connection
- Figure 4.25: PC Connection Properties
- Figure 4.26: Change Connection
- Figure 4.27: Change Connection
- Figure 4.28: COM1 Set
- Figure 4.29: Microsoft ActiveSync
- Figure 4.30: Select Connection Setting
- Figure 4.31: Configure Connection Setting
- Figure 4.32: Get Connected
- Figure 4.33: Run Repllog.exe on the TPC
- Figure 4.34: Connection on the TPC
- Figure 4.35: Connection on the Host PC
- Figure 4.36: Explore the TPC
- 4.2.3 Network via USB Client Port
- 4.3 Application Program Development
- 4.4 Wireless LAN Utility for TPC-61S
- Appendix A Watchdog Timer Programming
- Appendix B Fuse Specifications
- Appendix C Pin Assignments
3 Chapter 1
1.2.2 I/O Ports
• 3 serial ports: two RS-232 (COM1, COM2); one RS-485 (COM4) or
one RS-232(COM3)
• 1 RJ-45 Ethernet port
• 2 USB ports compliant with USB 1.1: one USB Host (Type A) and one
USB Client (Type B)
• 1 CompactFlash 2.0 type I/II slot
1.2.3 Storage
TPC-60S panel computers provide two methods for storage. One is the
on-board 64 MB NAND flash and the other one is a CompactFlash card.
The system boot-sequence is:
• If there is no CompactFlash card installed, the system will automati-
cally boot from the on-board NAND Flash.
• CompactFlash card only: the system will boot from CompactFlash card
1.2.4 Safety and Environment
Safety
• FCC Class B, CE and BSMI certified
• The front bezel is compliant with NEMA 4
Environment
• Operating Temperature: 0~50° C
• Storage Temperature: -20~70° C
• Humidity: 10~95% @ 40° C relative humidity (non-condensing)
• Vibration:
10~18 Hz @ 1.5mm peak-to-peak displacement
18~500 Hz @ 1G acceleration
Note TPS-60S provides three serial ports. The third
one can be set as COM3 for RS-232 or COM4 for
RS-485.
Note: It is suggested to use hardware flow control in
order to avoid data loss.