Specifications
SSBP-3000C
Page 29
6. PRE-POWER AND SYSTEM CHECKOUT
This Section describes the pre-power procedure for the SSPB and an initial checkout of the
system.
6.1 PRE-POWER PROCEDURES
Before applying power to the SSPB, verify that the following conditions are met:
1. The voltage of the station’s AC prime power matches with the value marked on the ID label. It
is 180-264 VAC for this unit.
2. The prime power station is properly grounded.
4. All cable and waveguide connections are secure and there is no evidence of pinched wires and
loose hardware.
5. The circuit breaker at the prime power station is switched OFF.
6. The L-Band input and RF output ports are connected to a matched source and a proper load
capable to withstand full CW RF power.
7. The cooling fans are not obstructed.
6.2 OPERATIONAL SETTINGS VERIFICATION
The SSPB arrives with all of its factory-pre-set operational values that meet the requirements of a
typical installation. Before starting the unit at the installation site, check the configurable settings
and if necessary, reset to meet the customer’s requirements.
WARNING: The
information presented in this Section is addressed to technicians having
specific training in and knowledge of Microwave Power Transmitters. Inappropriate use of
the SSPB may cause serious injury to the operator or result in damage to the unit. Do not
a
ttempt to operate the SSPB before becoming thoroughly familiar with the contents outlined in
this Section.
CAUTION: Failure to verify these pre-
power conditions may damage the SSPB or cause a
malfunction. Operating the SSPB before verification may void the warranty.