32 PCL-848AB User's Manual
3.4.15. REHOTE
Purpose:
This command places a device in Remote Mode. It can be addressed to a specific
device or to the interface, which just sets the REN line true.
Offset:
REMOTE%=33
Syntax :
CALL REMOTE&(ADDR%) ----BASIC
CALL ABSOLUTE(ADDR%,REMOTE%) ----BASIC Compiler
Parameter :
ADDR% - The address of the device to be set to remote. If 0<=addr<=30,
the specified device is set to remote. Otherwise, just the REN
line is set true.
Bus Activity :
- If 0 <= addr <= 30
REN is set true.
ATN is set true.
UNL is sent.
LAD is sent.
MTA is sent.
- If addr < 0 or addr > 30
REN is set true.