3.2.2 Power on Configuration after Hot Reset (JP1)
Use JP1 to set the hot reset type of PCIE-1744.
3.2.3 Input Terminator Select (JP2 to JP5)
Use JP2 to JP5 to set input terminator values for each AI channel (CH0 to
CH3)..
JP1 Power on configuration after hot reset
Keep the hardware register setting after hot
reset.
Load the hardware register default setting
after hot reset. (Default setting)
JP2, JP3, JP4, JP5 Input terminator select
50 ohm
1M ohm (Default setting)
High impedance