User manual

9 PCI-1762 User Manual
Chapter 2 Installation
Setting relay outputs to be NC/NO
Sixteen relay outputs, K0 ~ K15, are single-pole single-throw (SPST), which can be
jumper set as either normally open (NO) or normally close (NC) (see Table 2.2). The
default settings for K0 ~ K15 are normally open.
Setting the time to reset the relay outputs
Some users will want the capability of clearing each relay output when
Table 2.1: Summary of Jumper Settings
Names of Jumpers Function Description
JP4 ~ 19 Sets relay output to be normally open
Sets relay output to be normally closed
JP2 Keep last status after hot reset
Default configuration
Table 2.2: Summary of jumper settings for relay
Relay Output channel Corresponding Jumper
K0 JP4
K1 JP5
K2 JP6
K3 JP7
K4 JP8
K5 JP9
K6 JP10
K7 JP11
K8 JP12
K9 JP13
K10 JP14
K11 JP15
K12 JP16
K13 JP17
K14 JP18
K15 JP19