Specifications
26
Configuring the Device
Step 4: On the Device Setting dialog box (Fig. 2-6), you can configure
the voltage source either as External or Internal, and specify
the voltage output range for the two D/A channels.
Fig. 2-6 The Device Setting dialog box
Note:
? .Users can configure the source of D/A reference voltage either as
Internal or External, and select the output voltage range. When
selecting voltage source as Internal, users have two options for the
output voltage range : 0 ~ 5 V and 0 ~ 10 V.
? When selected as External, the output voltage range is determined by
the external reference voltage in the following way :
? By inputting an external reference voltage: -xV , where |x| <= 10,
you will get a output voltage range: 0 to xV.
Step 5: After you have finished configuring the device, click OK and
the device name will appear in the Installed Devices box as