User manual
Table Of Contents
- Chapter 1 Introduction
- Chapter 2 Hardware Configuration
- 2.1 Initial Inspection
- 2.2 Jumper and Switch Locations
- Figure 2.1: PCI-1601A/B Silk Screen
- Figure 2.2: PCI-1601AU/BU Silk Screen
- Figure 2.3: PCI-1602A/B Silk Screen
- Figure 2.4: PCI-1602AU/BU Silk Screen
- Figure 2.5: PCI-1602UP Silk Screen
- Figure 2.6: PCI-1603 Silk Screen
- Figure 2.7: PCI-1604UP Silk Screen
- Figure 2.8: PCI-1610A/B Silk Screen
- Figure 2.9: PCI-1610CU Silk Screen
- Figure 2.10: PCI-1610AUP/UP Silk Screen
- Figure 2.11: PCI-1610AJP Silk Screen
- Figure 2.12: PCI-1611U Silk Screen
- Figure 2.13: PCI-1612A/B Silk Screen
- Figure 2.14: PCI-1612AU/U Silk Screen
- Figure 2.15: PCI-1612CU Silk Screen
- Figure 2.16: PCI-1620A/B Silk Screen
- Figure 2.17: PCI-1620AU/U Silk Screen
- Figure 2.18: PCI-1622CU Silk Screen
- 2.3 Jumper Settings
- 2.3.1 How to Set Jumpers
- 2.3.2 Default Settings
- 2.3.3 Mode Selection by Jumper/DIP Settings
- Figure 2.21: PCI-1612 Series RS-232/422/485 Selection
- Figure 2.22: RS-422/485 Selection by Jumper Setting
- Figure 2.23: PCI-1603 RS-232 Mode Jumper Setting
- Figure 2.24: PCI-1603 Current-loop Mode Jumper Setting
- Figure 2.25: Active Mode Jumper Setting
- Figure 2.26: Passive Mode Jumper Setting
- Figure 2.27: Resistor Selection
- 2.4 Card Installation
- Chapter 3 Driver Setup & Installation
- Chapter 4 ICOM Tools
- Chapter 5 Pin Assignments and Wiring
PCI-COMMUNICATION User Manual 72
4.5.2 Message Logo Messages
Port Opened: The user has opened the port
Port Setup Fail: The user has set up the port configuration with parame-
ters that are either incorrect or unsupported.
Port Running: The port is running a test
Port Stopped: The test is stopped on the port
Tx Starting/Tx Stopped: transmitting starting/transmitting stop
Rx Starting/Rx Stopped : receiving starting/receiving stop
Break Error: a break event has been detected on the port
Framing Error: A timing error (i.e. from start bit to stop bit) has been
detected on the port
Port I/O Error: An incorrect I/O event has been detected on the port
Rx Overrun: Received data has been overwritten before being processed
Rx Buffer Full Error: The buffer on the receiving end is saturated so
that newly arrived data are ignored
Tx Buffer Full Error: The buffer on the transmitting end is saturated so
that the data transmitted by applications are ignored.
LB Error - %d: data error is detected in loop back
LB Rx Pending: Loop back mode is waiting for incoming data
Data Setup Error: parameter error in port configuration