Specifications

56 PCI-Comm Card Series User's Manual
<Performance Listing Area>
On the performance listing area, you can see the relevant information,
such as Rx Length (received packet byte length), Bytes/Sec (transmis-
sion rate) and Last Abnormal Status of each port running a test.
<Status Bar>
The Status Bar is where you can glimpse the current information of
the port you have selected. The Status Bar indicates whether the port
is READY, RUNNING, BUSY or STOPPED, N/A PORT and the
configuration information such as baud rate, data bit, stop bit, parity
bit and flow control (represented as 1200 N 8 1 None) settings. Also
we can see the duration of the test in hh:mm:ss format on the right.
For information about specific messages on this area, please refer to
Section 4.4, Messages on the Status Bar and Message Logo area.
Using the ICOM Tools utility
To launch the ICOM Tools testing utility, just access Start/Programs/
Advantech PCI Comm Tools/COM Examine Tools to start the port
testing utility.
Port Selection
Please follow the steps below to make your port selection:
Step1: Launch ICOM Tools, you will first see the Program Window