Specifications

16 PCI Comm Card Series User's Manual
RS-422/485 selection (for PCI-1601/1602/
1612)
You can set each port individually for either RS-422 (the default) or
RS-485 operation. The figure below shows the jumper settings. See
the "Jumper and Switch Locations" figure from page 7 to 11 for help
to locate the jumpers.
Enable mode selection
You set the Enable mode using two- or four- position DIP switches,
one for each port. If the switches are set to "AUTO", the driver auto-
matically senses the direction of the data flow and switches the
direction of transmission. No handshaking is necessary.
If DIP switches are set to "On," the driver is always enabled, and
always in high or low status. The user must select a mode before
beginning RS-422 applications.
Terminator resistor setup (for PCI-1601/
1602/1612)
You can install terminator resistors if necessary to match impedance.
Each signal line (RTS, CTS) has a separate resistor.
485485
485485
485
RS-485
RS-422 (default)
422422
422422
422
485485
485485
485
422422
422422
422
120
300