User manual

D.14 Mode R waveform
Non-Retriggerbale One-Shot with Edge Disarm
Mode R is identical to Mode F except that the counter will be disarmed
while an inactive-going Gate edge is applied to the counter. And the
counter will hold the count value until it is issued a LOAD command or
REST command.
SOURCE
COUNT
VALUE
TC OUTPUT
TC TOGGLED
OUTPUT
GATE
L-1 L-2 2 0
Mode R Waveforms
X L 1 L
SOURCE
COUNT
VALUE
TC OUTPUT
TC TOGGLED
OUTPUT
GATE
L-1 L-2 N+2 NX L N+1
64