User manual

D.8 Mode H waveform
Software-Triggered Delayed Pulse One-Shot with Hardware Gating
Mode H is identical to Mode G except that the Gate input is used to
qualify which source edges are to be counted. The counter must be
armed for counting to occur. Once armed, the counter will count all
source edges that occur while the Gate is active and disregard those
source edges that occur while the Gate is inactive. This permits the Gate
to turn the count process on and off.
As with Mode G, the counter will be reloaded from the Hold register on
the first TC and reloaded from the Load register and disarmed on the
second TC. This mode allows the Gate to control the extension of both
the initial output delay time and the pulse width.
SOURCE
WR
ARM
COMMAND
COUNT
VALUE
TC OUTPUT
TC TOGGLED
OUTPUT
Mode H Waveforms
GATE
X L L-1 L-2 K+1 K K-1 2 1 0 H H-1 H-2 N+1
SOURCE
WR
COUNT
VALUE
TC OUTPUT
TC TOGGLED
OUTPUT
GATE
N+1 N N-1 2 1 0 L
58