CM5 Count control (reload)
0 Reload from LOAD register
1 Reload from LOAD or HOLD register
CM6 Count control (special gate)
0 Disable special gate
1 Enable special gate
CM7 Count control (special gate)
0 Count on rising edge
1 Count on falling edge
CM11 ~ CM8 Count source selection
0000 Internal clock
0001 OUT N-1
0010 CLK N
0011 CLK N-1
0100 FOUT 0
0101 FOUT 1
0110 FOUT 2
0111 FOUT 3
1000 FOUT 4
1001 FOUT 5
1010 FOUT 6
1011 FOUT 7
1100 GATE N-1
1101 N/A
1110 N/A
1111 N/A
CM13 ~ CM12 Gate source selection
00 No gating
01 OUT N-1
10 GATE N
11 GATE N-1
37