2.4.8 Console Redirection Configuration
Figure 2.12 Configure Remote Access types and parameters
2.4.8.1 Remote Access
You can disable or enable the BIOS remote access feature here. The optimal and
fail-safe default setting is “Enabled”.
2.4.8.2 Serial Port Number
Select the serial port you want to use for console redirection. You can set the value
for this option to either ICH COM1 or ICH COM2. The optimal and fail-safe default
setting is ICH COM1.
2.4.8.3 Serial Port Mode
Select the baud rate you want the serial port to use for console redirection. The opti-
mal and fail-safe default setting is 115200 8, n, 1.
2.4.8.4 Flow Control
Select the flow control setting for the console re-direction - “None“, “Hardware“, and
“Software“. The default setting is “None“.