MIC-3392 User Manual 44
3.3.11 Serial over LAN
The MIC-3392 supports Serial over LAN (SOL). This can be used for implementing a
virtual remote serial terminal to enable user or remote software interaction with serial
interfaces for operating system and management services. SOL is implemented as a
payload type under the IPMI v2.0 “RMCP”+ protocol.
3.3.12 Serial/Modem Device Commands
Table 3.13: Threshold values of sensors
Sensor Number 01h 02h 03h 04h 05h 00h
Entity Instance 01h 01h 01h 01h 01h 01h
Nominal Reading 3.3 V 2.5 V 5 V 12 V 1.5 V 35° C
UNR N/A N/A N/A N/A N/A 55° C
UC 3.62 V 2.76 V 5.6 V 13.4 V 1.65 V N/A
UNC N/A N/A N/A N/A N/A 45° C
LNR N/A N/A N/A N/A N/A N/A
LC 2.96 V 2.24 V 4.4 V 10.6 V 1.2 V N/A
LNC N/A N/A N/A N/A N/A N/A
Positive-going 0x02 0x02 0x02 0x02 0x02
Negative-going 0x02 0x02 0x02 0x02 0x02
Table 3.14: Sensor Device Commands
Sensor Device Commands NetFn Cmd Mandatory /
Optional
Set Sensor Hysteresis S/E 0x24 O
Get Sensor Hysteresis S/E 0x25 O
Set Sensor Threshold S/E 0x26 O
Get Sensor Threshold S/E 0x27 O
Set Sensor Event Enable S/E 0x28 O
Get Sensor Event Enable S/E 0x29 O
Re-arm Sensor Events S/E 0x2a O
Get Sensor Event Status S/E 0x2b O
Get Sensor Reading S/E 0x2d M
Table 3.15: LAN Device Commands
LAN Device Commands NetFn Cmd Mandatory /
Optional
Set LAN Configuration Parameters Transport 0x01 M
Get LAN Configuration Parameters Transport 0x02 M
Table 3.16: Serial/Modem Device Commands
Serial/Modem Device Commands NetFn Cmd Mandatory /
Optional
Set Serial/Modem Configuration Parameters Transport 0x10 M
Get Serial/Modem Configuration Parameters Transport 0x11 M
Set Serial/Modem Mux Transport 0x12 M