MIC-3392MIL User Manual 58
4.3.11 Serial/Modem Device Commands
Table 4.13: Threshold values of sensors
Sensor Number 10h 11h 12h 13h 14h 15h 20h
Entity Instance 01h 01h 01h 01h 01h 01h 01h
Nominal Reading 1.2 V 1.5 V 3.3 V 12 V -12 V 1.8 V 30° C
UNR N/A N/A N/A N/A N/A N/A 55° C
UC 1.44 V 1.65 V 3.63 V 13.2 V -10.8 V 1.98 V 50° C
UNC N/A N/A N/A N/A N/A N/A N/A
LNR N/A N/A N/A N/A N/A N/A N/A
LC 0.8 V 1.35 V 2.97 V 10.8 V -13.2 V 1.62 V N/A
LNC N/A N/A N/A N/A N/A N/A N/A
Positive-going 0x02 0x02 0x02 0x02 0x02 0x02 0x02
Negative-going 0x02 0x02 0x02 0x02 0x02 0x02 0x02
Table 4.14: Sensor device commands
Sensor Device Command NetFn Cmd Mandatory / Optional
Set Sensor Hysteresis S/E 0x24 O
Get Sensor Hysteresis S/E 0x25 O
Set Sensor Threshold S/E 0x26 O
Get Sensor Threshold S/E 0x27 O
Set Sensor Event Enable S/E 0x28 O
Get Sensor Event Enable S/E 0x29 O
Re-arm Sensor Events S/E 0x2a O
Get Sensor Event Status S/E 0x2b O
Get Sensor Reading S/E 0x2d M
Table 4.15: Serial Modem device commands
Serial/Modem Device Command NetFn Cmd Mandatory / Optional
Set Serial/Modem Configuration
Parameters
Transport 0x10 M
Get Serial/Modem Configuration
Parameters
Transport 0x11 M
Set Serial/Modem Mux Transport 0x12 M