User manual
57 MIC-3392MIL User Manual
Chapter 4 IPMI for the MIC-3392MILS
4.3.10 Sensor and Threshold Configuration
Sensor data record (SDR) repository will be stored in BMC’s flash memory and can-
not be changed.
Note! UNC = Upper Non-Critical.
UC = Upper Critical
UNR = Upper Non-Recoverable
LNC = Lower Non-Critical
LC = Lower Critical
LNR = Lower Non-Recoverable
Table 4.12: Sensors list
Sensor Name
Sensor
Number
Sensor
Type
Reading
Type 
Sensor
Logged 
Assertions
Logged
De-assertions
Power Unit
Status
50h 09h 6Fh 00h - Power Off 00h - Power Off
04h - AC Lost
Watchdog
51h 23h 6Fh
00h - Timer 
Expired, status 
only
N/A
01h - Hard Reset
02h - Power Down
03h - Power Cycle
Power Failure 52h C0h 6Fh
00h - Power 
Failure
00h - Power 
Failure
SEL Full
07h - over 75% full
64h D0h 01h 09h - over 90% full N/A
0Bh - 100% full
System Temperature 20h 01 01h UC, UNR UC, UNR
W83627HG Vcore 10h 02h 01h LC, UC LC, UC
W83627HG +1.5 V 11h 02h 01h LC, UC LC, UC
W83627HG +3.3 V 12h 02h 01h LC, UC LC, UC
W83627HG +12 V 13h 02h 01h LC, UC LC, UC
W83627HG -12 V 14h 02h 01h LC, UC LC, UC
W83627HG +1.8 V 15h 02h 01h LC, UC LC, UC
Note! A chassis intruder sensor is not used on the MIC-3392MIL platform.
Power failure sensor type “C0h" indicates a power failure event.
Apart from the following list of sensors, other sensors should be reinitial-
ized when the system is powered on or reset.
- VCC
- SEL Fullness
- System PWR monitor
- Watchdog