3.2.5.2 Modify Temperature Limit for Pre-heat Circuit Activation (TEMP_PREHEAT)
The index register for TEMP_PREHEAT is 0x20 (see Table 3.1). The default value for
the pre-heat circuit activation is “E2” (-30° C), which can be modified as follows.
! For example, change the temperature limit from -30° C (E2) to -20° C (EC).
! On the “-” prompt, type in “o 294 20” and press <Enter>
! On the “-” prompt, type in “o 290 ec” and press <Enter>
! On the “-” prompt, type in “o 294 20” and press <Enter>
! On the “-” prompt, type in “i 290” and press <Enter>
! And, the response shown on the display is “ec”, representing -20° C.
! At this point, the new setting will be stored automatically in the SEEPROM.
3.2.5.3 Change Pre-heat Mode (PREHEAT_MODE)
The index register for PREHEAT_MODE is 0x30 (see Table 3.1). Its default value is
0x01 (i.e. extended pre-heat mode). To change it to the standard mode (0x00), refer
to the following steps.
! On the “-” prompt, type in “o 294 30” and press <Enter>
! On the “-” prompt, type in “o 290 00” and press <Enter>
! On the “-” prompt, type in “o 294 30” and press <Enter>
! On the “-” prompt, type in “i 290” and press <Enter>
! And, the response shown on the display is “00”, representing standard pre-heat
mode.
! At this point, the new setting will be stored automatically in the SEEPROM.
3.2.5.4 Exit Debug32
Every time a new value is keyed in to a configurable data register, it will be stored
automatically in the SEEPROM. The value will not change until it is re-configured by
the user again. To exit the pre-heat configuration mode, type in “quit” on the “-
”prompt.
Note! It is recommended that the data value for TEMP_PREHEAT does not
exceed -5° C (FB).