1.1 Specifications
1.1.1 General Specifications
• Input Voltage : 24~48V
DC
± 10%
• Operating Temperature: -10 ~ 50° C
• Storage Temperature: -40 ~ 85° C
• Operating Humidity : 5 ~95%
• Storage Humidity : 5 ~95%
• Voltage Tolerance (Output Voltage) : 5%
• Over Load Protection (OLP): 110 ~ 160%
•Min Load: 0A
• Max Load: 5A
• Over Voltage Protection (OVP): 115 ~ 165%
• Safety Standards: UL EN60950-1, CB EN60950-1 2001, EMC
• Input connector spec: DECA MC211-F103
• Output connector spec: GOAL RAY EH003-157
• Dimension: (WxHxD) : 61 x 35.4 x 168.5 mm (2.4”x1.39”x 6.63”)
• Weight: Net ( 0.35kg), Gross (0.38kg)
1.1.2 Output Specifications
Model O/P
Volts
Adj.±%
Load (current) Ripple
& Noise
Line
REG.
Load
REG.
Efficiency O.V.P.
Trip
point
Min Rated Max
PWR-
246E
12V±5%
0A 5A 5A N/A ±5%@
10% full
load
80% min. N/A