EKI-6333AC-2G Series User Manual 16
Electromagnetic Interference (EMI) affects the transmission performance of a device.
By properly grounding the device to earth ground through a drain wire, you can setup
the best possible noise immunity and emissions.
Figure 2.16 Grounding Connection
By connecting the ground terminal by drain wire to earth ground, the device and
chassis can be ground.
2.3 Reset Button
Reset configuration to factory default:
Press and hold Reset button for 5 seconds.
System reboot:
Note! Before applying power to the grounded device, it is advisable to use a
volt meter to ensure there is no voltage difference between the power
supply’s negative output terminal and the grounding point on the device.
LAN 1
PWR
LAN 2
5GHz
2.4GHz
Drain Wire with Lug
Connection to