User Manual

Table Of Contents
EKI-6331AN-BE/EKI-6332GN-AE User Manual 48
6.1 System Log
System log is used for recording events occurred on the IEEE 802.11n VAC Access
Point, including station connection, disconnection, system reboot and etc.
Open “System Log” in “Tools” as below.
Figure 6.1 Syslog
Remote Syslog Server:
Enable System log to alert remote server.
IP Address: Specify the IP address of the remote server.
Port: Specify the port number of the remote server.
6.2 Ping Watch Dog
If you mess your connection up and cut off your ability the log in to the unit, the ping
watchdog has a chance to reboot due to loss of connectivity.
Figure 6.2 Ping Watchdog
Enable Ping Watchdog:
To activate ping watchdog, check this checkbox.
IP Address to Ping:
Specify the IP address of the remote unit to ping.