62 EKI-6233BN User Manual
– parity n: None Parity.
– parity e: Even Parity.
– parity o: Odd Parity.
– parity m: Mark Parity.
– parity s: Space Parity.
Usage: port [nn|all] mode [vcom|ctrl|data]
Set the serial ports as virtual COM mode, control mode, or data mode.
5.3.4 mvcom
Usage: mvcom
Show all serial ports mode and related information.
Usage: mvcom [nn|all]
Set the “nn”
th
or all serial ports as the Virtual COM mode.
Usage: mvcom [nn|all] idleto []
Set the “nn”
th
or all serial ports host idle timeout(S).
Usage: mvcom [nn|all] respto [] framebk []
Set the “nn”
th
or all serial ports response timeout and frame break.
Usage: mvcom [nn|all] bysize []
Set datapackage as size(bytes).
Value 0 : None Setting.
Usage: mvcom [nn|all] bytime []
Set datapackage as time(ms).