User manual
37 EKI-1521/1522/1524 User Manual
Chapter 3 Configuration
Set the number of network device which you want to connect. You can set maximum
sixteen network devices which you want to connect. You need to fill out the IP
Address and Port (including local port and peer port) of network devices which you
want to connect.
Data Pack 
Data pack means you can set condition of receiving data from serial port to be a
package according to your application. There are four options to set the data packing:
by data size (Byte), by time interval (ms), by character timeout (4 Bytes), or by end of
character.
3.5.3 Control Mode (USDG Mode)
In controlling mode, the EKI-152X series presents a modem interface to the attached
serial device: it accepts AT-style modem commands to connect / disconnect to other