User's Manual

Advantech-DLoG DLT-V6210 Manual V1.00 Page 31 / 60
8. Power supply unit, power supply, external connectors
8.1. Integrated power supply unit
DLT-V6210 is equipped with a galvanically separated, integrated DC power supply unit.
Power is connected to the back of the unit using a Phoenix Contact plug.
There is no power switch.
Power supply
DC power pack
12/24/48 VDC
(wide-range power supply unit)
12/24/48 VDC nominal
Galvanically isolated
Withstands bursts up to 2 kV
Voltage range 9 to 60 VDC
Maximum output power Vin < 36V => 42W
Vin > 36V => 50.4W
Nominal current
12V -- 3.5A
24V -- 1.75A
48V -- 0.875A
Connection to SELV circuit only The SELV circuit is a secondary circuit that is designed
to protect from the voltage exceeding the safe value
when operation runs correctly or if a single error occurs.
Power consumption
DLT-V6210 Typically 34 W
Power supply unit fuses
Power supply unit Fuse type Example
Advantech Dlog
owned- design
power supply unit
5 x 20 mm, 8 A, 250 V LittleFuse 0477008.MXP
or similar product produced by other
manufacturers
The symbol of the fuse is FA. You will find the exact position on the sticker located on the connection
plate of DLT-V6210.