NOTICE: Physical damage
Installation environment without cooling air can overheat/damage DLT-V6210.
DLT-V6210 employs a passive cooling concept whereby the waste heat generated inside the
device is emitted from the surface of the housing.
For this system to work/operate properly, sufficient fresh air circulation is required.
If there is no access to fresh cooling air, it may result in overheating and severe damage to the
device.
Never install the system in a closed environment where the cooling air is unable to dissipate
accumulated heat to the outside.
The maximum permissible ambient temperature for the entire system needs to be taken into
account for the specific application area.
5.1.2. Secure attachment
Observe the following information about the mounting brackets:
All brackets and mounting parts supplied by Advantech-DLoG are only intended to be used for
attachment of the industrial PCs and the peripheral devices and may not be misused.
Only use suitable mounting brackets and screws permitted by Advantech-DLoG.
Ensure that ball-and-socket bases and mounting brackets are always attached correctly.
Please observe the mounting instructions supplied with the optional brackets.
DANGER
Risk of accident on the target objects due to unexpected emergency stop because of
electroconductive connection of DLT-V6210 to the targeted object chassis.
Due to a variety of technical properties of forklifts and forklift trucks, it can be necessary to
electrically isolate DLT-V6210 from the chassis of the targeted object to prevent malfunctions.
The necessity of this must be studied on a case-by-case basis, however, it is recommended for
targeted objects’ with potential-free chassis.
For example, using rubber buffers ensures that the terminal has no
electrically conducting connection to the chassis.
If peripheral equipment (such as scanners, printers, scales or similar) which
has its own power supply unit to be used, you must ensure that the power
supply units of these peripherals are galvanically separated from the supply
of the targeted obect. Moreover, the peripheral equipment and its cabling
must be attached electrically isolated.
If antennas are being used, you must ens
ure that the antennas are
isolated at the mounting point on the targeted object chassis.