User's Manual
Technical Data – Device
DLT-V72 Series User Manual V2.74
34 / 189
5.2. Environmental conditions
DLT-V72 without integrated UPS
Operating temperature
-30 to +50 °C
Specification according to EN 60068-2-1/2
Storage temperature
-30 to +65 °C
Specification according to EN 60068-2-1/2
Relative humidity
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP protection class
IP65 and IP66 for:
DLT-V7210
DLT-V7212
DLT-V7212 P+
DLT-V7215 P+
IP65 for:
DLT-V7210 K
DLT-V7210 KD
DLT-V72 with integrated UPS (optional)
Operating temperature
-30 to +50 °C
Specification according to EN 60068-2-1/2
Storage temperature
-30 to +60 °C
Specification according to EN 60068-2-1/2
Charging temperature
-10 to +50 °C (ambient temperature)
Relative humidity
10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP protection class
IP65 and IP66 for:
DLT-V7210
DLT-V7212
DLT-V7212 P+
DLT-V7215 P+
IP65 for:
DLT-V7210 K
DLT-V7210 KD