User's Manual

Optional Equipment
161 / 189
14.1. Integrated UPS (optional)
The DLT-V72 is optionally available with an integrated UPS. The battery pack of the UPS
is located in the battery pocket of the device.
Fig. 14.1: Battery pocket with UPS DLT-V72
WARNING
Personal injury due to short-circuit, fire, chemical burns,
toxic substances
DLT-V72 devices with integrated UPS contain battery packs.
These can ignite if handled or stored improperly (risk of fire),
cause chemical burns or release toxic substances.
1. Use care when handling battery packs.
2. Please observe manual section 2.3 Battery pack safety .
14.1.1. Battery pack specifications
Battery pack (Lithium-Ion technology)
Bridging time
The integrated UPS can bridge an interruption of the main
supply for typically 20 minutes. Requirement: The battery
pack is fully charged.
Operating temperature
-30 to +50 °C
Charging time
4 h (fully recharge a completely discharged battery pack).
Charging temperature
-10 to +50 °C (ambient temperature)
Storage temperature
-30 to +60 °C
Maximum output power
40 W
Battery voltage
7,2 V
Battery capacity
2000 mAh