Operating Instructions
Table Of Contents
- 1. Introduction
- 2. Technical customer support
- 3. Functional description
- 4. Unpacking, transporting, storing
- 5. Technical data – Device
- 6. Technical data – Radio modules (all optional)
- 7. Operation
- 8. General device configuration
- 9. Wi-Fi configuration
- 10. WWAN configuration
- 11. Mechanical installation
- 12. Electrical installation, cable connection, cable cover
- 13. Connectors
- 14. Integrated power supply, power supply cable
- 15. Optional equipment
- 16. Maintenance
- 17. Malfunctions and troubleshooting
- 18. Reasonably foreseeable misuse
- 19. Guidelines and certificates
- 20. End-of-life device disposal
- 21. List of figures
Technical data – Device
DLT-V72 Operating Instructions V2.50 Preliminary 15 / 140
Internal speaker, sound
The DLT-V72 is equipped with an internal speaker as standard (2 W).
The system messages from the industrial PC are output via this speaker.
The internal speaker is configured in the audio settings for the operating system in question.
5.2. Environmental conditions
5.2.1. DLT-V72 without integrated UPS
Operating temperature -30 to +50 °C
Specification according to EN 60068-2-1/2
Storage temperature -30 to +65 °C
Specification according to EN 60068-2-1/2
Relative humidity 10% to 90% at 40 °C relative humidity
Noncondensing
Specification according to EN 60068-2-3
Mechanical vibration
and shock resistance
Class 5M3 according to EN 60721-3-5
US Highway Truck according to MIL-STD 810F
IP protection class IP66 for DLT-V7210 and DLT-V7212
IP65 for DLT-V7210K
5.2.2. DLT-V72 with integrated UPS (optional)
The environmental conditions are described in the following chapter:
15.1 Integrated UPS (optional)